研究室発表論文
- I. Ueta, S. Masuda, R. Kataoka, "Determination of Volatile Organic Compounds Released by Trichoderma Species and Plant Endophytic Fungi using a Needle-Type Extraction Device and Gas Chromatography-Mass Spectrometry", Anal. Sci., in press.
- I. Ueta, S. Masuda, D. Kondo, R. Kikuchi, K. Nakagami, Y. Saito, "Functional Polytetrafluoroethylene Membrane-Assisted Purge and Trap Detection of Residual Solvents in Pharmaceutical Formulations Using a Needle-Type Extraction Device", Chromatography, in press.
- I. Ueta, D. Kondo, S. Masuda, Y. Ariizumi, R. Kikuchi, K. Nakagami, Y. Saito, "Dynamic Extraction of Residual Solvents from Pharmaceutical Formulations using a Needle-Type Extraction Device", Anal. Sci., 41, 79-83 (2025).
- I. Ueta, M. Hayashibe, K. Nakagami, Y. Saito, "Purge and Trap Extraction of Musty Odor Compounds by Thermal Desorption Tube Packed with Polydimethylsiloxane-Coated Macroporous Silica Adsorbent", Chromatography, 45, 133-137 (2024).
- I. Ueta, H. Suzuki, T. Koyama, Y. Saito, "Adsorption of Gaseous Organic Compounds onto PM2.5 During Air Sampling", Chromatography, 45, 79-83 (2024).
- I. Ueta, K. Sumiya, K. Fujimura, Y. Ariizumi, R. Kikuchi, K. Kawata, Y. Saito, "Volatile Anticancer Drug Determination by Thermal Desorption Technique with Polydimethylsiloxane-Coated Macroporous Silica Adsorbent in Gas Chromatography-Mass Spectrometry", Anal. Sci., 40, 3-8 (2024).
- I. Ueta, S. Kamei, K. Nakagami, Y. Saito, "Determination of Volatile Polycyclic Aromatic Hydrocarbons in Soil Using Needle-Type Extraction", Chromatography, 44, 139-143 (2023).
- I. Ueta, H. Makabe, S. Masuda, K. Nakagami, Y. Saito, "Foam-Eliminatory Purge-and-Trap Technique Using a Functional PTFE Membrane and Needle-Type Extraction Device to Determine Flavors in Drink Samples", Chromatography, 44, 133-137 (2023).
- I. Ueta, E. Kato, Y. Saito, "Sampling Bag-Based Emission Chamber for Measuring Volatile Organic Compounds from Household Materials using Solid-Phase Extraction-Type Collection Device", Anal. Sci., 39, 1615-1621 (2023).
- I. Ueta, M. Hayashibe, K. Sumiya, Y. Ariizumi, K. Fujimura, Y. Saito, "Polydimethylsiloxane-coated Macroporous Silica Adsorbent in Thermal Desorption Gas Chromatography", J. Chromatogr. Open, 3, 100084 (2023).
- I. Ueta, S. Kawamura, Y. Saito, "Miniaturized Liquid Extraction Cartridge with a Functional Porous Polytetrafluoroethylene Membrane for the Determination of Formaldehyde in Gaseous Samples", Sep. Sci. Plus, 6, 2300033 (2023).
- I. Ueta, D. Kato, M. Nagao, "Preconcentration of Hydrogen Selenide using Hydride Generation and Purge-and-Trap Collection for the determination of Selenium in Water Samples by Atomic Absorption Spectrometry", Int. J. Environ. Anal. Chem., 102, 7817-7823 (2022).
- I. Ueta, S. Kamei, Y. Saito, "Needle Extraction Device for Rapid and Quantitative Gas Chromatographic Determination of Volatile Chlorinated Hydrocarbons and Benzene in Soil", J. Chromatogr. A, 1685, 463586 (2022).
- I. Ueta, T. Komatsu, K. Nakagami, Y. Saito, "Super Absorbent Polymer for Water Removing Process Followed by a Needle-Type Extraction to the Effective Collection of Methanol in Water Samples", Chromatography, 43, 127-132 (2022).
- I. Ueta, A. Miyazaki, S. Yano, R. Kikuchi, K. Nakagami, Y. Saito, K. Kawata, "Evaluation of Volatility of Bendamustine Using Solid Phase Extraction-Type Extraction Device", Chromatography, 43, 87-91 (2022).
- I. Ueta, T Komatsu, K. Fujimura, Y. Saito, "Porous Membrane-Assisted Purge and Trap Sampling for Determination of VOCs in Gas Chromatography with Needle-Type Extraction Device", Chromatographia, 85, 7-12 (2022).
- I. Ueta, T. Koyama, K. Sumiya, Y. Saito, "Quantitative Determination of Gaseous Alkanes Adsorbed on Filter Paper During PM2.5 Sampling", Chromatography 42, 115-118 (2021).
- I. Ueta, K. Sumiya, K. Fujimura, T. Yoshimura, R. Kikuchi, Y. Saito, K. Kawata, "Extraction of Volatile Anticancer Drugs in Air using Solid-Phase Extraction Type Device followed by Gas Chromatography-Mass Spectrometric Analysis", Anal. Sci., 37, 341-345 (2021).
- I. Ueta, R. Takenaka, K. Fujimura, T. Yoshimura, S. Narukami, S. Mochizuki, T. Maeda, "Simultaneous Extraction and Determination of Volatile Organic Compounds and Semi-volatile Organic Compounds in Indoor Air using Multi-bed Solid Phase Extraction Device", Anal. Sci., 36, 1071-1074 (2020).
- I. Ueta, M. Sakamoto, K. Tani, Y. Saito, "Titanium Dioxide as a Packing Material for Micro-Packed Column in Gas Chromatography" Chromatography, 41, 97-101 (2020).
- I. Ueta, N. Sekiguchi, A. Suzuki, Y. Kobayashi, T. Kuwabara, Y. Saito, "Carbon Dioxide Laser Supersonic Drawing Nanofiber Sheet for Extraction of Polycyclic Aromatic Hydrocarbons in Water Samples", Chromatography, 41, 85-89 (2020).
- I. Ueta, N. Sekiguchi, A. Suzuki, Y. Kobayashi, T. Kuwabara, Y. Saito, "Polyethylene Terephthalate Nanofiber Sheet as the Novel Extraction Medium for the Determination of Phthalates in Water Samples", Anal. Sci.,36, 277-281 (2020).
- I. Ueta, R. Takenaka, K. Fujimura, S. Narukami, T. Sasaki, T. Maeda, "Quantitative Determination of 2-Ethyl-1-hexanol, Texanol and TXIB in In-door Air using a Solid-Phase Extraction-Type Collection Device followed by Gas Chromatography-Mass Spectrometry", Anal. Sci., 35, 855-859 (2019).
- I. Ueta, H. Fujikawa, K. Fujimura, Y. Saito, "Purge-and-trap Determination of Ammonia in Water Samples Using Needle-Type Extraction Coupled with Gas Chromatography-Barrier Discharge Ionization Detection", Anal. Sci., 35, 759-762 (2019).
- I. Ueta, M. Kajimoto, Y. Saito, "Purge-and-Trap Extraction with a Miniaturized Extraction Capillary for the Determination of Aqueous Formic Acids in Ion Chromatography", Chromatography, 40, 33-37 (2019).
- I. Ueta, Y. Nakamura, H. Fujikawa, K. Fujimura, Y. Saito, "Determination of Volatile Amines Using Needle-Type Extraction Coupled with Gas Chromatography-Barrier Discharge Ionization Detection", Chromatographia, 82, 317-323 (2019).
- I. Ueta, N. Sekiguchi, K. Fujimura, T. Yoshimura, S. Narukami, S. Mochizuki, T. Sasaki, T. Maeda, "Determination of Airborne Polycyclic Aromatic Hydrocarbons by HPLC Using SPE-Type Collection Device", Chromatography, 39, 119-124 (2018).
- I. Ueta, R. Takenaka, K. Fujimura, T. Yoshimura, S. Narukami, S. Mochizuki, T. Sasaki, T. Maeda, "Quantitative Determination of Phthalate Esters from Air Sample using a Solid-Phase Extraction-Type Collection Device", Anal. Sci., 34, 1149-1153 (2018).
- I. Ueta, H. Fujikawa, K. Fujimura, T. Yoshimura, S. Narukami, S. Mochizuki, T. Sasaki, T. Maeda, "Analysis of Biogenic Volatile Organic Compounds in Air Using a Solid-Phase Extraction-Type Collection Device", Chromatography, 39, 27-32 (2018).
- I. Ueta, Y. Nakamura, S. Kawakubo, Y. Saito, "Determination of Aqueous Formic and Acetic Acids by Purge-and-Trap Analysis with a Needle-Type Extraction Device and Gas Chromatography Barrier Discharge Ionization Detector", Anal. Sci., 34, 201-205 (2018).
- I. Ueta, M. Onikata, K. Fujimura, T. Yoshimura, S. Narukami, S. Mochizuki, T. Sasaki, T. Maeda, "A Newly Designed Solid-Phase Extraction-Type Collection Device for Precise Determination of Polycyclic Aromatic Hydrocarbons in Air", Anal. Sci., 33(10), 1175-1180 (2017).
- I. Ueta, Y. Nakamura, K. Fujimura, S. Kawakubo, Y. Saito, "Determination of Gaseous Formic and Acetic Acids by a Needle-Type Extraction Device coupled to a Gas Chromatography-Barrier Discharge Ionization Detector", Chromatographia, 80, 151-156 (2017).
- I. Ueta, M. Onikata, K. Fujimura, T. Yoshimura, S. Narukami, S. Mochizuki, T. Sasaki, T. Maeda, "Polydimethylsiloxane Coated Partitioning Sample Collection Device for the Precise Quantification of Polycyclic Aromatic Hydrocarbons in Air", J. Sep. Sci., 39, 4202-4208 (2016).
- I. Ueta, M. Onikata, K. Fujimura, T. Sasaki, T. Yoshimura, S. Mochizuki, T. Maeda, "Determination of Airborne Semi-Volatile Polycyclic Aromatic Hydrocarbons by Partitioning-Type Extraction Device Packed with Octadecyl-Derivatized Macroporous Silica", Chromatography, 37(1), 9-13 (2016).
- I. Ueta, T. Mitsumori, Y. Suzuki, S. Kawakubo, Y. Saito, "Purge-and-Trap Analysis of Flavor Compounds in Aqueous Samples by a Needle-Type Extraction Device", Chromatography, 36(3), 99-104 (2015).
- I. Ueta, M. Onikata, S. Mochizuki, K. Fujimura, T. Sasaki, J. Aoki, T. Maeda, "Partitioning Sample Collection/Solvent Extraction Cartridge Packed with Octadecyl-Derivatized Macroporous Silica Particles for the Analysis of Sesquiterpenes in Air Samples", J. Sep. Sci., 38(22), 3891-3896 (2015).
- I. Ueta, T. Mitsumori, Y. Suzuki, S. Kawakubo, Y. Saito, "Determination of Very Volatile Organic Compounds in Water Samples by Purge and Trap Analysis with a Needle-Type Extraction Device", J. Chromatogr. A, 1397, 27-31 (2015).
- I. Ueta, S. Mochizuki, S. Kawakubo, T. Kuwabara, Y. Saito, "Determination of Formaldehyde in Aqueous Samples with a Miniaturized Extraction Capillary Coupled to High-Performance Liquid Chromatography", Anal. Sci., 31(2), 99-103 (2015).
- I. Ueta, S. Mochizuki, S. Kawakubo, T. Kuwabara, K. Jinno, Y. Saito, "A Novel Miniaturized Extraction Capillary for Determining Gaseous Formaldehyde by High-Performance Liquid Chromatography", Anal. Bioanal. Chem., 407, 899-905 (2015).
- I. Ueta, T. Mitsumori, S. Kawakubo, Y. Saito, "Determination of Musty Odor Compounds in Water by Gas Chromatography-Mass Spectrometry with a Needle-Type Sample Preparation Device", Anal. Sci., 30(10), 979-983 (2014).
- I. Ueta, A. Mizuguchi, K. Tani, S. Kawakubo, Y. Saito, "Evaluation of Thermal Catalytic Decomposition of Organic Compounds with TiO2 by Packed-Capillary Gas Chromatography", Anal. Sci., 30(3), 407-412 (2014).
- I. Ueta, A. Mizuguchi, M. Okamoto, H. Sakamaki, M. Hosoe, M. Ishiguro, Y. Saito, "Determination of Breath Isoprene and Acetone Concentration with a Needle-Type Extraction Device in Gas Chromatography-Mass Spectrometry", Clin. Chim. Acta, 430, 156-159 (2014).
- I. Ueta, E.L. Samsudin, A. Mizuguchi, H. Takeuchi, T. Shinki, S. Kawakubo, Y. Saito, "Double-Bed-Type Extraction Needle Packed with Activated-Carbon-Based Sorbents for Very Volatile Organic Compounds",J. Pharm. Biomed. Anal., 88, 423-428 (2014).
- I. Ueta, N.A. Razak, A. Mizuguchi, S. Kawakubo, Y. Saito, K. Jinno, "Needle-Type Extraction Device for the Purge and Trap Analysis of 23 Volatile Organic Compounds in Tap Water", J. Chromatogr. A, 1317, 211-216 (2013).
- I. Ueta, A. Mizuguchi, K. Tani, S. Kawakubo, Y. Saito, "Rapid Temperature-Programmed Separation of Carbon Monoxide and Carbon Dioxide on a Packed Capillary Column in Gas Chromatography: Application to the Evaluation of Photocatalytic Activity of TiO2", Anal. Sci., 29(6), 673-676 (2013).
- M. Inoue, A. Mizuguchi, I. Ueta, K. Takahashi, Y. Saito, "Rapid On-Site Air Sampling with a Needle Extraction Device for Evaluating the Indoor Air Environment in School Facilities", Anal. Sci., 29(5), 519-525 (2013).
- I. Ueta, K. Takahashi, Y. Saito; "Column Switching Analysis with Packed-Capillary Columns in Gas Chromatography", Anal. Sci., 28(10), 953-957 (2012).
- I. Ueta, A. Mizuguchi, K. Fujimura, S. Kawakubo, Y. Saito, "Novel Sample Preparation Technique with Needle-Type Micro-Extraction Device for Volatile Organic Compounds in Indoor Air Samples", Anal. Chim. Acta, 746, 77-83 (2012).
- I. Ueta, Y. Saito, K. Teraoka, H. Matsuura, K. Fujimura, K. Jinno, "Novel Fire Investigation Technique Using Needle Extraction in Gas Chromatography", Anal. Sci., 26(11), 1127-1132 (2010).
- I. Ueta, Y. Saito, K. Teraoka, T. Miura, K. Jinno, "Determination of Volatile Organic Compounds for a Systematic Evaluation of Third-Hand Smoking", Anal. Sci., 26(5), 569-574 (2010).
研究室発表総説 (2010〜)
- I. Ueta, K. Nakagami, Y. Saito, "Solid-Phase-Extraction Device for Extracting Volatile Organic Compounds from Gaseous Samples", Anal. Sci., in press.
- 植田 郁生, 齊戸 美弘, "針型濃縮デバイスを用いる水試料中の揮発性有機化合物の分析" "Determination of Volatile Organic Compounds in Aqueous Samples by Needle-Type Extraction Device",分析化学(総合論文)(BUNSEKI KAGAKU), 65(1), 25-32 (2016).
- I. Ueta, Y. Saito, "Narrow Bore Packed Column Designed for Capillary Gas Chromatograph", Chromatography, 35(1), 41-48 (2014).
- I. Ueta, Y. Saito, "Needle-Type Extraction Device Designed for Rapid and Sensitive Analysis in Gas Chromatography", Anal. Sci., 30(1), 105-110 (2014).
- I. Ueta, "Sample Preparation of Volatile Organic Compounds with Needle-Type Extraction Device", Chromatography, 34(1), 23-31 (2013).
- 植田 郁生, 齊戸 美弘, "ガスクロマトグラフィーのための針型試料前処理デバイス" "Needle-Type Sample Preparation Devices for Gas Chromatographic Analysis", 分析化学(総合論文)(BUNSEKI KAGAKU), 60(11), 833-844 (2011).